Axisymmetric Bluff Body Turbulent Flow
Code name: | B3F1 |
Wind Tunnel Dimension (m): | 0.305 * 0.305 |
Jet Diameter (m): | 0.0046 |
Bluff Body Diameter (m): | 0.0600 |
Fuel mixture: | CH3OH = 100% (by vol.) |
Stoichiometric Mixture Fraction: | 0.1350 |
Blowoff velocity (m/s): | 117.0 |
Wind tunnel air velocity (m/s): | 20 |
Open flame, No enclosure |
The following values have been used in calculating the
mixture fraction:
Total Mass fraction of Oxygen atoms in the air stream, Zo,o =
0.233
Total Mass fraction of Carbon atoms in the air stream, Zc,o =
0.0
Total Mass fraction of Hydrogen atoms in the air stream, Zh,o = 0.0
Total Mass fraction of Oxygen atoms in the fuel stream, Zo,f =
0.4995
Total Mass fraction of Carbon atoms in the fuel stream, Zc,f =
0.3746
Total Mass fraction of Hydrogen atoms in the fuel stream, Zh,f = 0.1259
Data files provided for this fuel mixture: (to download the files click here)
Jet velocity Axial location Radial Location Our
Ref. Filenames
(m/s)
(x/D) (mm)
-------------------------------------------------------------------------
82.2
1.5 08 bmrout.654 b3f1s15.01
82.2 1.5 08 bmrout.655 b3f1s15.02
99.3 1.5 08 bmrout.650 b3f1l15.01
106.3 1.5 08 bmrout.652 b3f1m15.01
106.3 1.5 08 bmrout.653 b3f1m15.02
113.3 1.5 08 bmrout.651 b3f1n15.01
DISCLAIMER: No responsibility is assumed by the suppliers of this data for any injury and/or property damage as a matter of products liability, negligence or otherwise, or from any use or operation of any methods, products, instructions, or ideas based on these data.
© 2002-10 The University of Sydney. Last updated: 1 Sept 2010
ABN: 15 211 513 464. CRICOS number: 00026A. Phone: +61 2 9351 2341.